- IPL Machine[10]
- Laser Beauty Equipment[3]
- Microdermabrasion Machine[10]
- Multi-Functional Beauty Equipment[10]
- No-Needle Mesotherapy Device[10]
- Other Beauty Equipment[10]
- Oxygen Jet[8]
- RF Equipment[4]
- Skin Analyzer[2]
- Spa Capsule[2]
- Vacuum Cavitation System[6]
- Breast Enhancement Cream[2]
- Other Breast Care Products[1]
- Other Skin Care Tool[3]
- Other Bathroom Furniture[1]
- Contact Person : Ms. Xiao Finna
- Company Name : Guangzhou Leety Beauty Equipment Co., Ltd.
- Tel : 86-20-86297128
- Fax : 86-20-86297098
- Address : Guangdong,Guangzhou,Room 301 Jiahe Hotel Jiahe Street,Baiyun District
- Country/Region : China
- Zip : 510000
Related Product Searches:Far Infrared Sauna & Detox Instrument (LB-8808),High Quality,Far Infrared Sauna & Detox Instrument, far infrared facial sauna,LB-8808
Far Infrared Sauna & Detox Instrument
Working Principle & Efficacy
Air Pressure De-toxin
Air pressure can promote lymph circulation and drain away waste inside the body. It is different from the traditional vibration treatment, it use air bag to give a full pressure to exercise body fat. The beautician use different massage way with help of the instrument, can accelerate lymph circulation and drain out waste, keep lymph system run smooth.
Air de-toxin is applying soft air pressure to make massage on body, it will not make any hurt and uncomfortable feeling to body. Meanwhile, the pressure is equal to 50kg, this weight makes effect to belly for 30 minutes is equal to 150 times sit-up.
Far Infrared Sauna
Fat dissolve: Far infrared heat directly make effect to fat tissue, make fat cell dissolve and liquefy.
Fat contract: Far infrared heat focus to increase temperature of body, expand skin pore, drain away sweat in large quantity. The water of fat cell is drained out, in this way to reduce volume of fat cell.
Relax muscle: Far infrared heat can reduce the muscle extension, relief muscle convulsion.
Others: Diminish inflammation, cool pain, stimulate tissue regeneration, soft scar.
Operation Step
Air de-toxin treatment operation step:
1, Install the accessory to the mainframe
2, Power on machine
3, Adjust air pressure mode (refer to panel introduction NO.4), the left data on the screen is 1 to 4, there are total 4 modes:
Mode 1, Air pressure output one by one:
Four air pressure output one by one, when first output finish inflate to first group air bag, the second output start to inflate to second group air bag, according to the order goes on.
Mode 2, Air pressure output two by two:
Two air pressure output inflate to two group air bag, it is suitable to make treatment for arm and abdomen.
Mode 3, All air pressure output:
All air pressure output work, in a time inflate to four group air bad.
Mode 4: Only two group of air pressure output.
4, Adjust air pressure mode (refer to panel introduction NO.4), the right data on the screen is 1 to 6, they represent 6s, 9s, 12s, 15s, 20s, 25s. (6s means air pressure 6 seconds and relief 6 seconds, and other is the same meaning).
5, Select intensity (refer to panel introduction NO. 7) to adjust air pressure intensity, press start/ pause (refer to panel introduction NO. 6) to start or pause air pressure function.
Far infrared treatment operation step:
1, Press select (refer to panel introduction NO. 10) to select output, the corresponding indication light is on ( refer to panel introduction NO.8).
2, Press up/down (refer to panel introduction NO.11) to adjust far infrared temperature ( temperature range is from 35-85 degree, within 7 seconds), it is subject to client’s feeling, but the skin temperature should not more than 45 degree. After 5 seconds of the temperature setting, the system will go back to display current working temperature. If there is a red point on the temperature display, it means the temperature till not reach the setting data, if the red point disappear, it means the temperature has reached to setting data. Press start/pause (refer to panel introduction NO.12) to start or stop far infrared function.
3, After finishing the treatment, power off the machine, clean and sterilize the accessory and reserve it for next treatment.
Safety Notice
1, Please don’t disassemble the equipment or try to do some other operation, which have been indicated in our instruction. All the repairing work should be done by our admitted professional personal.
2, Please don’t assemble or operate this equipment while you are near the water or your hands are wet. Notice that don’t pour the liquid on it.
3, Please pull out the plug from the socket when you met such conditions as below, and keep in touch with professional maintenance station.
A, the equipment touched liquid
B, the equipment has abnormal smell, smoking or loud and strong noise
C, Cable was broken
D, the equipment was fallen down and broken
4, Please don’t put anything on the cables, don’t place the equipment at anyplace where someone can step on the cable.
5, Please pull out the power cable after using it for your safety.
6, Don't put anything into the equipment’s jack, otherwise it may cause fire or touch the electricity. If something enters the equipment, please don’t pick it out by yourself, contract distributor or our company immediately.
7, Please don’t put the equipment on the anything that can’t stand steadily, avoid it turns over and damage.
8, Our company reserves the right to modify the information in this introduction before notify! And keep the explanations right for the above.
Attention:
If the supply cord is damaged, it must be replaced by manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Packing List
Name | Unit | Qty | Remark |
Main Machine | Set | 1 | |
Power Wire | Pcs | 1 | |
Air Pressure & Infrared Belt | Set | 1 | 5 pcs |
Fuse | Pcs | 2 | |
Instruction Manual | Pcs | 1 |